The transducer series P 50000 was specifically designed for applications on locomotives and multiple units for short circuit recognition, monitoring and control of traction motors and inverters, auxiliary inverters, accumulator batteries and others.
Brand new is the flexibility through switchable measurement ranges and an integrated broad-range power supply.
ProLine P 51000 at a glance
Overload protected current measurement via shunt resistor from amps to kiloamps
4800 V AC/DC protection at PD3, OV3 according to EN 50124-1, UL 347
18 kV AC test voltage
Particularly low measurement error < 0.1 % of meas. value + 0.1 % f.s
Floating standard signal output (switchable: 0/4 ... 20 mA, 0 ... 10 V) and additional monitoring output
Integrated broad-range power supply (16.8) 24 to 230 (253) V DC/AC
Fire and smoke: hazardous level HL3 to EN 45545-2:2016
Suited for use on railway vehicles: EN 50125-1/-2 and EN 50155
RAMS: diagnostics contact for device status, MTBF 155/38 years (ground benign/ground mobile)
Resistant against vibration and mechanical shock to EN 61373 (railway applications)
EMC to EN 50121-1, EN 50121-3-2 (railway applications) and EN 61326-1 (industrial applications)
Contact protection through protective cover, housing with IP protection up to IP54 (HV side), IP33 (LV side)
Suited for energy measurement to EN 50463-2 (1.0 R)
Isolation coordination to EN 50124-1, EN 50123-1 (railway) and EN 50178, UL 347 (industry)