西門子PLC S7-1500 CPU模塊 軟控制器 US2:74JR36DFAP

點擊圖片查看原圖
品牌: 西門子
單價: 面議
所在地: 北京
有效期至: 長期有效
最后更新: 2021-07-05 15:37
瀏覽次數(shù): 216
詢價
店鋪基本資料信息
 
產(chǎn)品詳細說明
西門   PLC CPU模塊

CPU 1507S  V 2.x(1個浮點授權), 僅能在SIMATIC IPC上使用
產(chǎn)品細節(jié)
封閉型軟起動器, 控制器 3RW40471BB14, 標準負載額定值 30Hp /200V, 標準負載電流額定值 98A, 控制電壓 110-230 AC/DC, 組合式, 17*** 斷路器, 外殼類型 3/3R, 抗風化,可室外使用 CPT 標準容量 480/240:120V CPT 標準容量 480/240:120V

技術數(shù)據(jù)

 
Enclosed soft starter, Controller 3RW40471BB14, Std duty rating 30Hp @200V, Std duty current rating 98A, Control voltage 110-230 AC/DC, Combination type, 17*** circuit breaker, Enclosure type 3/3R, Weather proof outdoor use CPT Std Capacity 480/240:120V CPT Std Capacity 480/240:120V
product brand name Class 74
design of the product Enclosed soft starter with motor circuit protector
special product feature Control transformer, built-in overload relay and bypass contactor included.
General technical data
weight [lb] 87 lb
Height x Width x Depth [in] 46 × 20 × 10 in
touch protection against electrical shock NA for enclosed products
installation altitude [ft] at height above sea level maximum 6560 ft
ambient temperature [°F]  
● during storage -22 ... +149 °F
● during operation -4 ... +104 °F
ambient temperature  
● during storage -30 ... +65 °C
● during operation -20 ... +40 °C
country of origin USA
Power and control electronics
manufacturer's article number of soft starter 3RW40471BB14
number of poles for main current circuit 3
design of power semiconductors (thyristors) for soft starter control 2 controlled phases
operating range factor supply voltage rated value 0.85 ... 1.1
operating range factor of control voltage rated value 0.85 ... 1.1
operating condition for standard duty Class 10 standard duty (350% of motor FLA for 10 seconds)
operating condition for severe duty NA
Features and functions
ramp-up (soft starting)/ramp-down (soft stop) Yes
starting voltage [%] 40 ... 100 %
stopping voltage [%] 40 ... 100 %
voltage ramp Yes
ramp-up time 0 ... 20 s
ramp-down time 0 ... 20 s
torque control No
adjustable current limitation Yes
creep speed in both directions of rotation No
pump ramp down No
integrated bypass contact system Yes
external isolation contactor Yes
intrinsic device protection Yes
overload protection Yes
trip class Class 5 / 15 / 20
reset function Manual, automatic and remote
remote reset function No
thermistor motor protection No
inside-delta circuit No
breakaway pulse No
DC braking No
combined braking No
motor heating No
configuration of control input 1 ON / OFF
configuration of control input 2 NA
configuration of control input 3 NA
configuration of control input 4 NA
configuration of relay output 1 ON / RUN
configuration of relay output 2 BYPASSED
configuration of relay output 3 OVERLOAD / FAILURE
configuration of relay output 4 NA
display version 4 LEDs
operating measured value display No
product extension optional human machine interface module No
type of communication optional None
error logbook No
event list No
slave pointer function No
trace function No
number of parameter sets 1
engineering software (Soft Starter ES) No
disconnector functionality Yes
Contactor
size of contactor NA
Coil
type of voltage of the control supply voltage AC/DC
control supply voltage  
● at DC rated value 110 ... 230 V
● at AC at 50 Hz rated value 110 ... 230 V
● at AC at 60 Hz rated value 110 ... 230 V
Enclosure
degree of protection NEMA rating 3, 3R
degree of protection NEMA rating of the enclosure NEMA 3/3R
design of the housing Weather proof for outdoor use
type of cooling None
Circuit Breaker
type of the motor protection Motor circuit protector (magnetic trip only)
operational current of motor circuit breaker rated value 175 A
adjustable current response value current of instantaneous short-circuit trip unit 900 ... 2000 A
Mounting/wiring
mounting position Vertical
fastening method Surface mounting and installation
wire length between motor starter and motor maximum 300 m
type of electrical connection for supply voltage line-side Box lug
type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded 1x (6 AWG ... 350 Kcmil) or 1x (4 AWG ... 350 Kcmil)
temperature of the conductor for supply maximum permissible 75 °C
material of the conductor for supply AL or CU
type of electrical connection for load-side outgoing feeder Box lug
tightening torque [lbf·in] for load-side outgoing feeder 58 ... 58 lbf·in
type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multi-stranded 3x (10 ... 1/0 AWG) (front only) or 2x (10 ... 1/0 AWG) (back only) or 1x (10 ... 2/0 AWG) (both front & back)
temperature of the conductor for load-side outgoing feeder maximum permissible 75 °C
material of the conductor for load-side outgoing feeder CU
type of electrical connection for auxiliary and control circuit Screw-type terminals
tightening torque [lbf·in] for auxiliary and control contacts with screw-type terminals 7 ... 10 lbf·in
type of connectable conductor cross-sections at AWG cables for auxiliary and control contacts 2x (20 ... 14 AWG)
temperature of the conductor for auxiliary and control contacts maximum permissible 75 °C
material of the conductor for auxiliary and control contacts CU
Short-circuit current rating
design of the short-circuit trip Motor circuit protector (magnetic trip only)
breaking capacity maximum short-circuit current (Icu)  
● at 240 V 42 kA
● at 480 V 42 kA
● at 600 V 0 kA
certificate of suitability NEMA ICS 2; UL 508A
Further information
Industrial Controls - Product Overview (Catalogs, Brochures,…)
Industry Mall (Online ordering system)
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
Certificates/approvals
US2:74JR36DFAP