Explosion proof enclosure rated Class I Division 1 Groups B-D, Ex d IIB+H2, AEx d IIB+H2
Intrinsically Safe Rated Class I, Div 1, Groups A-G, Ex ia IIC, AEx ia IIC
Non-Incendive Class I Div 2 A-D, Ex nA
Selection | Standard | Code | Example |
3 | 3 | ||
Protocol | Foundation Fieldbus* | 4 | 4 |
Diagnostics | Standard Diagnostics* | 0 | 2 |
Advanced Diagnostics | 1 | ||
Pro Diagnostics 2 | 2 | ||
Housing & Brand | Aluminum, White Paint (Valtek)* | 0 | 0 |
Stainless Steel, No Paint (Valtek) | 1 | ||
Aluminum, Black Paint (Automax) | 2 | ||
Aluminum, Food Grade White Paint (Automax) | 3 | ||
Aluminum, Accord (Black Paint) | 4 | ||
Aluminum, Accord (Food-Grade White Paint) | 5 | ||
Design Version | MD | MD | |
Certifications | Explosion proof Class I, Div 1, Groups B, C, D, DIP Class II, III, Division 1 E, F, G | 01 | 01 |
Intrinsically Safe Class I, Div 1, Groups A,B,C,D Nonincendive Class I, II, III, Division 2 A, B, C, D, E, F, G | 02 | ||
INMETRO Ex ia IIC T4; Ex d IIB+H2 T5 (South America) | 06 | ||
Flame Proof Ex d IIB+H2; ATEX II 2 G | 07 | ||
General Purpose | 14 | ||
Ex ia IIC, ATEX II 1 G | 15 | ||
IECEx Ex d IIB + H2 | 16 | ||
Ex nA nL IIC, ATEX II 3 G | 20 | ||
IECEx Ex ia IIC | 21 | ||
ATEX Multiple Protection Mylar Nameplate:II 2 G Ex d IIB+H2; II 1 G Ex ia IIC | 28 | ||
North American Multiple Protection Mylar Nameplate: Explosion proof, Intrinsically Safe Non-Incendive | 34 | ||
TRCU | 44 | ||
Shaft/Feedback Shaft | DD 316 SSl Shaft (Valtek Standard)* | D6 | D6 |
NAMUR 316 SSl (VDI/VDE 3845) | N6 | ||
Conduit Connections/Threaded Connections | 1/2" NPT | E | E |
M20 | M | ||
Action | 4-way (Double-Acting) | 04 | 04 |
3-way (Single-Acting) | 03 | ||
3-way Purge (Single-Acting) not for use with natural gas (used to purge springs side of actuator with instrument air) |
3P | ||
4-way Vented (Double-Acting) | 4V | ||
3-way Vented (Single-Acting) | 3V | ||
Temperature | Low -40°C to 85°C (-40°F to 185°F)* | 40 | 40 |
Gauges | Gauges (Valtek standard)* | 0G | 0G |
SS with SS internals, psi (bar/kPa) | 0S | ||
SS with SS internals, psi (kg/cm2) | KS | ||
SS with brass internals, psi (kg/cm2) | KG | ||
No Gauges | 0U | ||
Special Options | None* | 00 | 00 |
Remote Mount Feedback (Only available with Certification Option 14) | RM | ||
Fail Option Feedback** | SF | ||
*Indicates Standard Product Configuration | |||
**Contact factory before specifying this option. |
Local status LED's
Local DIP Switches/Calibration Buttons
Auto Tuning with dynamic gain selection
AO, DI, DO, OS, IS and PID blocks are provide in all Logix® 3400MD's
Simple calibration via local interface